Install the insulation panels over the entire surface to be insulated. Compatible with all pipes dimensions: 13 mm [1/2] to 25 mm [1]. Snow and ice melt applications for driveways, patios and walkways. Less physically demanding and easy to install by one person. KITCHEN, BATHROOM ETC. ISORAD V2 | R3-R5 allows you to easily meet building code and construction requirements for energy-efficient standards, such as Novoclimat, Energy Star and Passive House. Multi-unit. Quick and easy walk-in installation of PEX tubing without the need for staples and zip ties and completely eliminating the strain of working at 45 degree angles. Maximizes occupant comfort. 2022 Fries Tallman - All rights reserved. Discuss products and projects with your online Modlar community. PEX tubing is then easily inserted into the panels simply by walking in the tubing. The larger contact area between the tubing and the concrete allows for increased heat transfer reducing the response time of the system and helping achieve desired temperatures faster. Unique product that offers compression strength of 110 kPa [16 psi] for residential applications up to 414 kPa [60 psi] for industrial applications. Protection of the honeycomb surface through sandwich shipped panels. shipping, 64 sqft (2ft x 4ft, 8 panels) Crete-Heat 2" Foam Board Insulation for 3/8", 1/2" & 5/8" PEX, R-10, Save ${{ Automobile establishments including garages, car washes and dealerships, Agricultural applications such as workshops and barns, Heated floors in distribution centres, manufacturing assembly and storage. Easy installation: Reduces the number of components and steps required to install the system. Compatible with all pipes dimensions: 13 mm [1/2], 16 mm [5/8], 20 mm [3/4] and 25 mm [1]. Concrete is poured on top of the panel to the required thickness (as per local code) encasing the tubing, nubs and any steel reinforcement (optional rebar or welded wire mesh). High-density interlocking panels. The 2x4 (610x1220mm) panels are placed on compacted stone/gravel. The innovative patented panel design ensures that the tubing is completely encased in concrete and not pushed to the bottom of the panel through the use of bridge connectors. Orders with Free Ground Shipping also qualify! Our team of experts will help you. Better contact with concrete. Even distributionofwarmth / heat. Available in a variety of compression strengths: 110 kPa [16 PSI] for residential applications until 414 kPa [60 PSI] for industrial applications. Learn how your comment data is processed. International locations include Mexico, Ireland, Romania and Russia. Tips and Tricks Multidirectional honeycomb-layout. The large, four-sided interlocking shiplap connector system makes for a quick, easy and secure installation while maintaining the continuity of the vapor barrier and eliminating the need for a dedicated 6 mil. QUICK AND EASY INSTALLATION: Quick and easy walk-in installation of PEX tubing without the need for staples and zip ties and completely eliminating the strain of working at 45-degree angles. kitchen, bathroom etc. reviews[i].content.location }}), {{ Holds up to foot traffic when installing the tubing. Amvic Ampex R10 28 PSI radiant insulation panels have unique mushroom shaped nubs which locks the PEX tubing firmly in place (staples and zip ties not needed). INSTALLATION: GREATER EFFICIENCY The Ampex panels have unique mushroom shaped nubs which locks the PEX tubing firmly in place (staples and zip ties not needed). polyethylene (unless specifically required by local building code). Tubing can be easily inserted between the pucks by walking on it. Configurationthat permits concrete flow under the pipe. U.S locations include Nixa, MO; Charlotte, NC; Salt Lake City, UT; Post Falls, ID; and Anchorage, AK. Contributes to the soundproofing of the slab by uncoupling the radiant slab. Uniform heat transfer for an efficient, comfortable and warm living space. CCMC # 13638-L: Compliant to ULC-S701-11, EPS type 3, CAN/CSAB214, Installation Code for Hydronic Heating Systems, R-value required. REDUCES WASTE AT SITE: Light and manageable panel size reduces waste due to damage on site. 2022 Copyright Amvic Inc. All Rights Reserved. DURABLE INSTALLATION: The nub height accommodates multiple tube sizes and protects the tubing from damage when the panel is walked upon by other trades. Pipes fixed accordingto desired configuration. This process does not require you to purchase the product - it can be easily Energy efficient. SNOW AND ICE MELT APPLICATIONS FOR DRIVEWAYS, PATIOS AND WALKWAYS. The panel combines rigid insulation, a vapor barrier and PEX tubing locking mechanism into a single solution that significantly reduces installation time. document.getElementById( "ak_js_1" ).setAttribute( "value", ( new Date() ).getTime() ); This site uses Akismet to reduce spam. Since our price for this product is lower then MAP, the manufacturer does not allow Can be installed on concrete slab or on wooden subfloor provided for this purpose. Pipes holding holdfirmlyin place.Does not lift during concrete pouring. To take advantage of our new, super-fast delivery option, simply select Ground Shipping method in Cart or Checkout. Compliance Certification is available upon request. Whats the Difference Between Wirsbo and PEX? manufacturer's established MAP ("Minimum Advertised Price"). Multidirectional tube retention system. Squareflo.com. Amvic's exceptional network of facilities enables us to produce incomparable products that can be delivered promptly anywhere in North America. Technical questions ? Light and manageable panel size reduces waste due to damage on site. manufacturers to educate them on how MAP affects our customers. For installation under a concrete slab-on-grade or below ground level, a minimum insulation value of R10 is generally required. Amvic has also aligned with several factories in the United States and internationally to produce high quality, energy efficient products. Prevents panels from shifting and the creation of non-insulated gaps. Ensures regular intervals between the tubes. Your email address will not be published. reviews[i].feedback_count }}, {{ reviews[i].content.name manufacturers require internet retailers to display a price at or above The combination of molding expanded polystyrene (EPS) insulation, one of the highest performing energy efficient insulation materials available today, with a High Impact Polystyrene (HIPS) film, makes for a strong and resilient Ampex panel. Sitemap | Privacy Policy | Terms & Conditions, Ampex Insulated Hydronic Radiant PEX Panel, Carbon Graphite Embedded EPS for Exterior Wall Insulation, Flat Sheet Rigid Foam Insulation With Integrated Furring, High Density Rigid Foam Reflective Insulation, High Density Flat Sheet Rigid Foam Insulation, Exterior Insulation Panel With a Vertical Drainage System, Rigid insulation panel for under slab depressurization systems, Ampex: Insulated Radiant Floor Heating Panel, Find a Dealer, Industry Professional or Territory Manager, Residential: 0.42 US perms (23.8 ng/Pa.s.m2). Large format expanded polystyrene insulating panel for water or glycol radiant flooring floor heating. 1219 mm x 2438 mm [48 x 96] panel. Eliminates the need for wire mesh and a plastic grid when only required to secure the tubes. Refer to applicable codes requirements in your area. Using ISORAD V2 R3-R5 requires the installation of insulation and tubing prior to pouring concrete needed to cover the heating system. By combining the insulation performance of an expanded polystyrene board with a multidirectional tube-retention system, ISORAD V2 R3-R5 provides the perfect solution for embedding a radiant heating system in concrete in upper storeys or renovation projects. Prevents heat loss through the floorto maximize the efficiency of the radiant heating system on upper floors or when renovating existing slabs or floors. }}, (from {{ / 100).toFixed(2) }} / each, {{ (2*reviews[i].feedback_helpful) - Residential. While PexUniverse.com reserves the legal right set its own product pricing, some ThermaTrace Self-Regulating Heating Cable. Water or gycol radiant floor heat system. For any existing floor installation in a renovation project, professional evaluation is recommended to ensure that the structure in place can bear the additional loads associated with the application, including concrete overload. images, {{ USDFormatter(Math.min(f.discount_price, f.sell_price)) }}, {{ USDFormatter(Math.min(f.discount_price, f.sell_price) * (f.quantity_per_mqty || 1) * f.qty) }}, {{ USDFormatter(f.sell_price * (f.quantity_per_mqty || 1) * f.qty) }}, Have the same billing and shipping address, Cuts labor by over 60% and allows for a 1-person installation - simply "walk the tubing in the board", Tongue & groove interlocking edges make installation easier - no glue or taping needed, Knob design allows for spacing in precise 3" increments (3", 6", 9", etc.) BUILT-IN VAPOR BARRIER: The large, four-sided interlocking shiplap connector system makes for a quick, easy and secure installation while maintaining the continuity of the vapor barrier and eliminating the need for a dedicated 6 mil. EFFICIENT SOLUTION FOR THE INSTALLATION OF RADIANT HEATING SYSTEMS ON UPPER STOREYS OR FOR RENOVATION. Superior and faster installation for hydronic radiant infloor heating. The 2x4 (610 x 1220 mm) panels are placed on compacted stone/gravel. Tall wall applications such as retail, gymnasium, banquet halls etc. ISORAD V2 R3 and R5 insulation panels are primarily intended for installation on a concrete slab or wooden subfloor. Durable panel with easy walk-in installation enabling increased job-site efficiency. Use glue or fasteners to affix the panels at the junction of the walls and to prevent concrete from seeping beneath them. What is the difference between each type of PEX? Refer to the installation recommendations and effective requirements in your area before any work starts. What is the difference between PEX A, B and C? Allows insertion of 1/2 or 5/8 internal diameter tubing*, Do not contain HFC nor HBCD that damage the ozone layer, Greenguard- and Greenguard Gold-certified products. Concrete is poured on top of the panel to the required thickness (as per local code) encasing the tubing, nubs and any steel reinforcement (optional rebar or welded wire mesh). Easy installation: Reduces the number of components and steps required to install the system. 3/4. PEX tubing is then easily inserted into the panels simply by walking in the tubing. Perfect overlap between panels through ship lap joints on 4 sides. *Videos are for information purposes only. We understand that this is an inconvenience and are continually working with LegendFlex Oxygen Barrier Expansion Tubing, VesiHeat PEX-c Tubing with Oxygen Barrier, Stainless Steel F1807 PEX Fittings (Crimp). Eliminatestheinstallationof metallic mesh [when not required for the slab reinforcement]. Covers more area in one panel Larger area coverage. TALL WALL APPLICATIONS SUCH AS RETAIL, GYMNASIUM, BANQUET HALLS ETC. No foamboard staplers/staples or wire ties needed. Laying the pattern as defined by the heating system professional, install the tubing by walking over it to secure it in place between the pucks. Faster installation by one person. View technical specifications and installation guides. Hydronic radiant heating and under-slab insulation, Flyer ISORAD, Radiant floor insulation product line, Compliance Certification is available upon request. Our services are exceptional and we strive for honest work in a caring and collaborative culture. This facilitates and accelerates installation of both insulation and the floor heating system. PEX tubing is then easily inserted into the panels simply by walking in the tubing. NEW AND RENOVATION Crete-Heat expanded polystyrene (EPS) floor insulation boards combine concrete insulation, vapor barrier and PEX tubing holding grid into a single product, which significantly simplifies installation of PEX tubing for radiant heating and snow melting applications in a concrete slab. SECURED AND RESISTANT PANELS (Math.round(Math.abs(pickupPrice) * 100) This option is available at no additional cost! Amvic Ampex R10 28 PSI radiant insulation panels have unique mushroom shaped nubs which locks the PEX tubing firmly in place (staples and zip ties not needed). Commercial. Certified low-chemical-emission product : Prepare the floor surface for the installation of insulation panels. 1 888 332-3456 Or write to us at [emailprotected]. 5/8, ext. Reduce your labour costs. HEATING SYSTEM FOR BASEMENTS AND OTHER LIVING AREAS E.G. polyethylene (unless specifically required by local building code). These factories are independently owned and operated by Amvic partners who share the same vision and manufacturing process as Amvic Toronto. 1/2, ext. ISORAD V2 | R3-R5 product is quick and easy to install. *THIS PRODUCT IS SUBJECT TO ADDITIONAL COD FREIGHT/TARIFF AND BROKERAGE CHARGES ON SHIPMENTS TO THE UNITED STATES*, Your email address will not be published. To ensure maximum insulating performance, follow the recommended installation practices. The nub height accommodates multiple tube sizes and protects the tubing from damage when the panel is walked upon by other trades. This allows us to continue offering our lowest prices while staying consistent with spacing), Total Insulation Thickness (Top to Bottom): 2-7/8", Effective Board Size (Width x Length): 24" x 48", Overall Board Size (Width x Length): 25" x 49" (with 1" interlocking edges), Compressive Resistance @ 10% Deformation: 25 psi / 3600 psf, Material: High Impact Extruded Polystyrene. Facilitates tube installation and the realization of separate heating zones from the hot water or glycol floor heating system. reviews[i].created_at | formatDate }}, {{ (2*f.feedback_helpful) - f.feedback_count }}, By PexUniverse Customer Service on {{ f.answered | formatDate }}, {{ USDFormatter(m.sell_price * m.quantity_per_mqty) }}, Max 8 Consistent grid pattern of the panel allows for uniform heat distribution. FREE FedEx Ground shipping on all orders over $99.00. *Tube 5/8: int. - no chalkline needed, Lays flat, can be walked on and helps to protect the pipe from damage during construction, EPS provides stable R-value and does not need to be adjusted for age, PEX Tubing Spacing: 3" (for 3", 6", 9", 12", etc. Required fields are marked *. Heating system for basements and other living areas e.g. We provide our products and services to communities in Saskatchewan through building projects small and large. For more information on slab-on-grade or below the ground slab application, see ISORAD V2 | R10-R15. As one of Saskatchewan's largest, most-respected retail lumber yards, with growing revenues FTL exists to make a difference. Innovative panel design with a mushroom-nub technology ensuring a durable, quick and simple install. Learn more about hydronic radiant heating systems and how the Ampex insulated PEX panel can provide superior comfort, improve the indoor air quality, reduce losses and contribute to substantial savings. Order now and we'll have your order ready in, Does not qualified for Amvic's primary manufacturing facility and head office is located in Toronto, Canada. REDUCES HEAT LOSS Increases occupant comfort and energy efficiency of the building. us to display our lowest price until you place the product in the shopping cart. *Tube 1/2: int. IDEAL TO DELINEATE HEATING ZONES Efficient thermal barrier. Thin configuration maximizes ceiling height. Call us to speak to our engineers, architects or representatives Spacing of 76 mm [3], 152 mm [6], 229 mm [9] and 305 mm [12]. product manufacturer's policy. IMPROVED THERMAL COMFORT: A consistent grid pattern of the panel allows for uniform heat distribution. To make the tubing turn easier, push or pull them so that they are in constant contact with the elevated pucks. AUTOMOBILE ESTABLISHMENTS INCLUDING GARAGES, CAR WASHES AND DEALERSHIPS, AGRICULTURAL APPLICATIONS SUCH AS WORKSHOPS AND BARNS, HEATED FLOORS IN DISTRIBUTION CENTRES, MANUFACTURING ASSEMBLY AND STORAGE. The 2x4 (610x1220mm) panels are placed on compacted stone/gravel. removed from shopping cart if needed. The four-sided interlocking system allows the panels to be quickly and easily positioned and ensures the alignment of the pucks for tubing installation. By combining rigid insulation panels and a tubing retention system into a single product, the step of fixing the tubes to a wire mesh or subfloor is eliminated. Vapor Permeance =Residential: 0.42 US perms (23.8 ng/Pa.s.m2). Amvic AmPEX 2 x 4 Radiant Insulation Panel R10, 30 PSI, Be the first to review Amvic AmPEX 2 x 4 Radiant Insulation Panel R10, 30 PSI. The Ampex panels have unique mushroom shaped nubs that lock the PEX tubing firmly in place (staples and zip ties not needed). Save time, labor on your radiant hydronic heating installations and achieve faster completion dates. Can contribute to obtainLEED credits. Not recommended for use over rough surfaces such as crushed stone. High-density material for increased resistance on the job site. Isolofoam expanded polystyrene insulation products are eco-responsible. All Amvic ICF and EPS facilities are equipped with top of the line machinery, which ensures that the highest quality of energy efficient products are manufactured consistently. Please provide your Zip code for delivery estimate. The Amvic Insulated Radiant PEX panel has been specifically designed to provide the most cost effective installation and performance characteristics for Hydronic Radiant floor heating systems. Hydronic radiant heating provides increased comfort and energy savings. Lightweight and quick and easy to install, with start arrows and integrated cutting lines. 5/8 Concrete is poured on top of the panel to the required thickness (as per local code) encasing the tubing, nubs, and any steel reinforcement (optional rebar or welded wire mesh). Residential: 0.42 US perms (23.8 ng/Pa.s.m2). Excellent retention of 1/2 or 5/8 tubing. Ensures continuous and uniform insulation.
Sitemap 21