This website uses cookies to improve your experience while you navigate through the website. Lightspeed, If you need a quote / large quantitie's / other questions / feel free to ask ! This design is optimal for easy penetration of tissue, septum rubber or packaging materials. For example, Free shipping on orders over USD $ 100.00 *, Data Communication and Human Input Devices, Defense, Security, Surveillance & Inspection, * Subject to approval and not available for products shipped by others sellers through the RobotShop Marketplace, My order was quickly processed and shipped. Awesome, The service is always exceptional, and the range of parts match the service!!!! Waterproof, battery-operated meter stands up to the most demanding field applications. The inner diameter of the POF is 2.0 mm. Because smaller probes use fewer precious metals, we can get the price lower. To do so, hair-thin sensors are inserted into the constructs and the oxygen content is measured online. Benchtop or portable instruments, probes, and sensors used to measure dissolved oxygen in water and other solutions; typically used to determine oxygen saturation or biological oxygen demand (BOD), a measure of biodegradable material in the sample. Cable length: 45cm (18) This type of measurement employs an electrode (comprising a cathode and anode usually inside a hollow cylindrical body) containing a 'filling solution' with the measuring end of the electrode covered with a plastic (usually Teflon or polethylene) film, across which oxygen molecules can diffuse. However you may visit Cookie Settings to provide a controlled consent. eDAQ offers: OtherClarkelectrodes and meters can be obtained from: If you buy the meter and electrode from the same manufacturer so make sure that the meter has an analog recorder output so that it will be compatible with the e-corder unit. Range1 50 mg/L Reliably measure dissolved oxygen (optical/polarographic) and temperature with this RDO/DO portable meter for advanced field analysis. Range: 1 50 mg/L By using our website, you agree to the usage of cookies to help us make this website better. What can I do? Reliably measure dissolved oxygen (RDO optical/polarographic) and temperature with this benchtop meter for advanced lab analysis. This was given to you on your receipt and in the confirmation email you should have received. Suitable for samples containing strong acids andhydrogen sulfide gas, 9551-20D (2m cable) 9551- 100D (10m cable), DO sensor tip, stainless steel DO sensor protective guard, DO sensor cap, air calibration bottle, stainless steel DO sensor protective guard, Galvanic vs Optical Dissolved Oxygen Sensors, Password Reset Procedure for LAQUA 1000 Series Bench Meters, Automatic Temperature Compensation in pH Measurement, LAQUAtwin pH Sensor Maintenance Procedures, LAQUAtwin Ion Sensor Maintenance Procedures, LAQUAtwin Conductivity Sensor Maintenance Procedures, Procedure for Setting mmol/L Unit in LAQUAtwin Ion Pocket Meters, pH Electrode Care and Maintenance Procedures, Conductivity Cell Care and Maintenance Procedures, Dissolved Oxygen Electrode Care and Maintenance Procedures, Electrical potential of Reference Electrode, Sample Measurement for low Conductivity Liquid/Low Buffer Capacity, Measurement for strongly acidic/basic aqueous solution, Measurement for sample including fluoride ion. Electrophoresis, Western Blotting and ELISA, Chromatography and Mass Spectrometry Reagents, Laboratory Syringe Needles and Accessories, Lab Coats, Aprons, and Other Safety Apparel, Sharps Disposal Containers and Accessories, Applied Biosystems TaqMan Assay and Arrays Search Tool, Applied Biosystems TaqMan Custom Assay Design Tools, Applied Biosystems Custom qPCR Primers and TaqMan Probes Tool, Thermo ScientificOrion Versa Star Pro DO Benchtop Meter, Thermo ScientificOrion Star A113 Dissolved Oxygen Benchtop Meter, Thermo ScientificOrion Star A123 Dissolved Oxygen Portable Meter, Thermo ScientificOrion Star A323 Dissolved Oxygen Portable Meter, Thermo ScientificOrion Star A223 Dissolved Oxygen Portable Meter, Thermo ScientificOrion Star A213 Dissolved Oxygen Benchtop Meter, FisherbrandTraceable Portable Dissolved Oxygen Meter, YSIPro2030 Field Dissolved Oxygen/Conductivity Meter, YSIEcoSense ODO200 Optical DO/Temperature Kit, FisherbrandTraceable Dissolved Oxygen Meter Pen, OHIOLUMEX CO INCFIRESTINGO2 OXYGEN METER, Cole-ParmerYSI 559 Replacement Dissolved Oxygen (DO) Sensor Module, Fisherbrandaccumet Research AR40 Benchtop Dissolved Oxygen Meter Kit, Thermo ScientificOrion 3-Star Plus Dissolved Oxygen Portable Meter, FisherbrandTraceable Portable Dissolved Oxygen Meter Pens, Mettler ToledoPortable Dissolved Oxygen Meters, OaktonWaterproof DO 450 Portable Dissolved Oxygen Meter, DO 450 meter kit w/optical probe, OaktonDO Six+ Portable Dissolved Oxygen Meters, YSIBenchtop Models 5100 Dissolved Oxygen Meters, Chemical Storage and Management Resource Center, Set point alarm, high/low limit alarm, calibration due alarm, Color graphic LCD with user-customizable options, English, Spanish, French, Italian, German, Chinese, Portuguese and Korean, Non-volatile memory preserves log and settings, Universal AC adapter (included) or 4 AA batteries (sold separately), 9 pin MiniDIN (polarographic DO sensor with built-in temperature), 4 AA batteries (included) or universal AC adapter (sold separately), Simple with highlighted measure key, scroll and shortcut keys, Non-volatile memory preserves data log, calibration log and meter settings, English, Spanish, French, Italian, German and Chinese; Portuguese and Korean available with software update, High/low limit alarm, calibration due alarm, Comprehensive with menu-specific function keys and dual purpose scroll/shortcut keys, 9 pin MiniDIN (RDO optical or polarographic DO sensor with built-in temperature), 9 pin MiniDIN (RDO optical or polarographic DO sensor with built-in temperature), stirrer input (stirrer probe), 3 years instrument, 2 years cable, 1 year polarographic sensor, 6 months galvanic sensors, 0 to 20mg/L, 2% of the reading, 20 to 50mg/L, 6% of the reading, RoHS, CE, WEEE, IP-67 waterproof, 1-meter drop test, 0 to 20mg/L, 0.3mg/L or 2% of reading, whichever is greater, 20 to 50mg/L, 6% of reading. All related tubing, flow meters, valves, and gauges come pre-installed on the Sample Calibration Panel. These cookies help provide information on metrics the number of visitors, bounce rate, traffic source, etc. Temperature range C The septum of the vial or package is pierced with the needle and the sensor is extended for measurement. Response time~0.5 mg/L/per sec 689 kPa (100PSI) Price Match lets you match the price of any item sold and shipped by RobotShop with a competitor's price! Connector: Male SMA Which substances can interfere with the optical O, Oxygen Microsensors NTH / IMP / PM / FTCM, Video: Manual Micromanipulator Set-up Adjustment, *after two-point calibration as described in the manual, Organic solvents, such as acetone, toluene, chloroform or methylene chloride, Two-point calibration with oxygen-free environment (nitrogen, sodium sulfite) and air-saturated environment, 60 months provided the sensor material is stored in the dark at room temperature, High spatial resolution (down to < 50m), Measures in liquids as well as in gas phase. 3.2 or 4.8 mm ID tubings, Luer lock adapters for 3.2 or 4.8 mm ID tubings, With integrated contactless optical oxygen sensor, 20 ml vial with integrated oxygen & temp sensor, Measures oxygen gas (%O2) or dissolved oxygen (DO), Sensor screw cap with integrated optical oxygen sensor, Minimize maintenance by simply exchanging the cap, Stainless steel 3cm long, 3mm in diameter, Stainless steel 20cm long, 3mm in diameter, Ultra-high speed response time (t90 < 0.3s). As the measurement is made inside the package no error-prone and time consuming sampling is necessary. © copyright 2002 - 2022 eDAQ - data recording made simple, © copyright 2002 - 2022 eDAQ - data recording made simple website by, © copyright 2002 - 2022 eDAQ - data recording made simple, Oxygen concentration can also be determined with special fibre optic probes and meters. How do I import data into excel from a text file containing measurement data? It is mounted inside a stainless steel needle, which protects the optical fiber and oxygen-sensitive sensor tip. These oxygen microsensors are ideal tools for quality control in the food & beverage, packaging, and pharmaceutical industries. To track your order please enter your Order ID in the box below and press the "Track" button. JavaScript seems to be disabled in your browser. All three sensor styles can be built in any measurement range (BOS1, BOS2, BOS3). This type of electrode is OK for student or routine use is usually avoided for accurate research use. Measurement method for single micro liter sample using Compact pH meter, Method for Measuring the pH of Samples that Generates Bubbles, Categorization of Ion electrodes by response membrane, General matters regarding measurement methods using ion selective electrodes, Measurement of Conductivity in Many Fields, Sample Measurement for low Conductivity Liquid, Methods for Measuring Dissolved Oxygen Levels, Measurement of Dissolved Oxygen Levels by the Diaphragm Electrode Method. Enter the competitor's price and the url where you found it and we will do our best to match this competitor's price. The. Because of this, they need to be refilled more frequently than full-size or industrial probes. Galvanic oxygen electrodes use a platinum cathode and a lead anode.Oxygen is spontaneously reduced at the cathode while the lead anode is slowly converted to lead oxide. Oxygen concentration can also be determined with special fibre optic probes and meters. Is there a recoating service for the needle-type microsensors? How do I measure the oxygen content in small headspace packages with a needle-type oxygen microsensor? Out of these cookies, the cookies that are categorized as necessary are stored on your browser as they are essential for the working of basic functionalities of the website. Thus only slow data acquisition rates (4 /s or slower) are usually required. # Hit enter to search or ESC to close. Portable meter provides reliable and high quality dissolved oxygen (DO) measurements with simple click of a button. Dissolved oxygen sensor in a small Ryton housing with 1 meter cable. The SCP-OXY Sample Calibration Panel provides an easy, pre-engineered solution for gas phase applications. Designed for small spaces, this small probe gives you the same quality readings found in our lab-grade Dissolved Oxygen just smaller. Keep in mind; smaller probes hold less electrolyte. These systems are more expensive than the use ofClarkor galvanic electrodes, but have the advantage of zero oxygen consumption, as well as electrical isolation. This is the principle of the: This electrode has an internal 'shorting resistor' so that the current flow is converted to a voltage signal so that it can be directly connected to any e-corder . These electrodes require a special meter to provide the polarising voltage and measure the current flow and convert it into a signal that the e-corder can record. Max pressure The cable has an outer diameter of 2.8 mm. This sensor is a miniaturized optical oxygen sensor designed for all research and packaging applications where a small tip size (< 50 m tapered sensor tip TS, < 140 m flat-broken sensor tip TF) and fast response time (t90 < 3 s) are necessary. PreSens Precision Sensing GmbHAm BioPark 1193053 Regensburg, GermanyPhone: +49 941 942 72 100Fax: +49 941 942 72 111E-mail. Full-featured, microprocessor-controlled meters for state-of-the-art performance. Fisherbrand Traceable Portable Dissolved Oxygen Meter Pen has a water-resistant design with O-ring seal and membrane keypad which assures a long life in severe lab or harsh plant environments. The PSC3-OXY provides a portable carrying case for trace level oxygen measurement in the field. The OXYvisor optical oxygen Analyzer is Barben Analyticals next generation solution for oxygen measurement in industrial applications. Take simple, accurate dissolved oxygen and temperature measurements with this benchtop meter with easy operation for basic lab testing. RobotShop is also a leading force in Robotics Education & Research. How does salinity affect the oxygen measurement? Any cookies that may not be particularly necessary for the website to function and is used specifically to collect user personal data via analytics, ads, other embedded contents are termed as non-necessary cookies. Barben Analytical offers optical oxygen analyzers utilizing quench luminescence technology. What is the correct way for handling an oxygen or pH microsensor? On the other hand the small signals obtained from such electrodes are more subject to inteference so shielding of the experiment is often important. The 4401 Optical Oxygen Analyzer provides some major advantages over traditional membrane style electrochemical sensors and zirconia cells. Response time: ~0.5 mg/L/per sec Because of this, they need to be refilled more frequently than full-size or industrial probes. The self-contained ruggedized and weather resistant case includes sample conditioning for wet, dirty natural gas with quick connect fittings for the sample inlet and outlet. These systems are more expensive than the use of, EIS Electrochemical Impedance Spectroscopy. Accuracy: +/ 0.2 mg/L Technical queries should be directed to the RobotShop Forum). High accuracy combined with economical pricing. 1x Syringe For use with ProODO, ProDSS, and 5500D instruments. This category only includes cookies that ensures basic functionalities and security features of the website. Watch tutorials, webinars and informative videos about PreSens optical sensor systems. Because of this, they need to be refilled more frequently than full-size or industrial probes. The 'Clark', (or polarographic, or amperometric) method uses a cathode that is held at a 'polarising voltage' of -0.7 V to -0.8 V which causes the reduction of oxygen, (i.e. We use cookies on our website to give you the most relevant experience by remembering your preferences and repeat visits. Max depth: 60 meters (197ft) Mini Lab Grade Dissolved Oxygen Probe Datasheet. * Free shipping is only available for products shipped by RobotShop. Internal temperature sensor The amount of current passed from the anode to the cathode is proportional to the oxygen content of the solution. Internal temperature sensor: No Easy-to-use dissolved oxygen meter provides accuracy, reliability and intuitive operation. The current flow from the anode to the cathode is proportional to the oxygen content of the solution. Thus you should ensure that the electrode you choose will consume oxygen at a rate much less than the reaction that you are trying to monitor. Order confirmation and Order shipped emails are the same day or next day. We also use third-party cookies that help us analyze and understand how you use this website. This type of oxygen sensor has an excellent long-term stability. Specify the panel, analyzer, BOS sensor, and RTD to get up and running quickly. Analytical cookies are used to understand how visitors interact with the website. Designed for small spaces, this small probe gives you the same quality readings found in our lab-grade Dissolved Oxygen just smaller. Accurately monitor dissolved oxygen (optical/polarographic) and temperature with this RDO/DO portable meter for challenging field testing. After penetration the sensor tip is extended for measurements. Oxygen microsensors measure the oxygen content in various volume compartments of the tissue engineering constructs. # Type at least 1 character to search Pro20 BOD Lab Kit includes everything from lab to field (or both) along with a probe. ~6 Months Included with Mini Dissolved Oxygen probe Grezi from Switzerland. Compact, rugged design with large, easy-to-read digits. 2020 RobotShop inc. All Rights Reserved.Putting robotics at your service is a trademark of RobotShop inc. Temperature range: C 1 50 C Reads: Dissolved Oxygen Manufacturers supply oxygen consumption specifications for their electrodes. Life expectancy: 2.5 Years Mini Lab Grade Dissolved Oxygen Probe Datasheet. /. ConnectorMale SMA Non-distribution item offered as a customer accommodation; additional freight charges may apply. ReadsDissolved Oxygen 2.5 Years 45cm (18) Get premium performance and flexibility with this benchtop meter with module for dissolved oxygen (optical/polarographic) and temperature. Measurement of sample including solvent other than water. We ship worldwide. Please, RDO optical dissolved oxygen sensor or polarographic dissolved oxygen sensor, Percent Saturation Range Polarographic DO, 400 to 850mmHg, automatic using built-in barometer or manual entry, 450 to 850mmHg, automatic with manual entry, Dissolved oxygen as % saturation or mg/L with temperature and barometric pressure, Dissolved oxygen as % saturation or mg/L with temperature. Therefore, determination of the oxygen content within packages or pharmaceutical vials is of essential importance to ensure both the filling quality and the long-term storage stability. Maintenance: ~6 Months, Included with Mini Dissolved Oxygen probe. Smaller probes use fewer precious metals and hold fewer electrolytes. It is also imporant to stir the solution at a constant rate throughout the experiment to ensure that the rate of diffusion also remains constant. Max pressure: 689 kPa (100PSI) e-corder low pass filters, down to 1 Hz, to ensure a noise-free signal. Is all of this coating sensitive to oxygen and where exactly do I measure? Witrox 1 oxygen meter for mini sensors (1 x O / 1 x temp), Witrox 4 oxygen meter for mini sensors (4 x O / 1 x temp). Because bothClarkand galvanic oxygen electrodes depend on the diffusion of oxygen from the sample solution into the electrode, their response time is slow - usually several seconds at best. Affordable optical RDO technology reduces maintenance time and costs. Accuracy+/ 0.2 mg/L DISCLAIMER: The appearance of a third party company or product on this page is for informational purposes and constitutes neither a recommendation nor an endorsement. - Powered by Please enter a valid email address. Can I measure inside a tissue with fiber optic microsensors? These cookies will be stored in your browser only with your consent. can be used with most polarographic electrodes and, because they are electrically isolated, they will not interfere with nearby pH or temperature probes. The BOS optical sensors are available in three installation styles: BOS FIBERSENSE - 4mm sensor for small tubing installations, BOS FLEXSENSE - Threaded sensor with removable luminophore sensor cap, BOS SAFETAP - Retractable hot tap sensor.

Sitemap 8